Xtralis
Xtralis
  • Видео 159
  • Просмотров 828 652
How the Improved VESDA-E System Works
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
Просмотров: 329

Видео

How the Improved VESDA-E System Works
Просмотров 593Месяц назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
DCD Lithium-ion Fire Prevention for Data Centers Broadcast: Investing in Safety and Lowering Risk
Просмотров 1414 месяца назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
DCD Tech Showcase: Discovering Versatile Solutions to Accommodate Lithium-ion Battery Systems
Просмотров 634 месяца назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
VESDA-E Accessories
Просмотров 1734 месяца назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
Xtralis University - EU & UK CC Payments and Training Registration
Просмотров 1745 месяцев назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
FAAST FLEX Upgrade Tutorial (Firmware Update Complier Tool)
Просмотров 5098 месяцев назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
Xtralis' Li-ion Tamer GEN 3: A Better, Safer Way of BESS Fire Detection
Просмотров 3,9 тыс.Год назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
Xtralis VIS-IR™ Failsafe Bi-Spectral Thermography Detector
Просмотров 1,1 тыс.Год назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
FAAST FLEX: Détection de Fumée par Aspiration
Просмотров 794Год назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
FAAST FLEX: Vorbereiten der Bluetooth-Verbindung
Просмотров 472Год назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
FAAST FLEX Anleitung: Änderung PIN
Просмотров 88Год назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
FAAST FLEX Anleitung: Wandinstallation
Просмотров 198Год назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
FAAST FLEX Anleitung: Verwendung von DIP-Schaltern
Просмотров 119Год назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
FAAST FLEX Anleitung: Luftstromabgleich
Просмотров 199Год назад
Xtralis provides powerful, early warning life safety and security solutions that prevent disasters, including VESDA aspirating smoke detection, ADPRO perimeter, multi-site and enterprise security systems, and HeiTel central monitoring solutions.
FAAST FLEX Anleitung: Inbetriebnahme und Konfiguration mittels DIP-Schalter
Просмотров 382Год назад
FAAST FLEX Anleitung: Inbetriebnahme und Konfiguration mittels DIP-Schalter
FAAST FLEX Anleitung: Gedrehte Wandmontage
Просмотров 54Год назад
FAAST FLEX Anleitung: Gedrehte Wandmontage
FAAST FLEX Anleitung: Austausch Lüfter
Просмотров 99Год назад
FAAST FLEX Anleitung: Austausch Lüfter
Procédure pour Bluetooth FAAST FLEX
Просмотров 564Год назад
Procédure pour Bluetooth FAAST FLEX
FAAST FLEX Procédure: Utilisation des Commutateurs DIP
Просмотров 241Год назад
FAAST FLEX Procédure: Utilisation des Commutateurs DIP
FAAST FLEX Procédure: Remplacement de L'aspirateur
Просмотров 194Год назад
FAAST FLEX Procédure: Remplacement de L'aspirateur
FAAST FLEX Procédure: Normalisation du Détecteur
Просмотров 342Год назад
FAAST FLEX Procédure: Normalisation du Détecteur
FAAST FLEX Procédure: Montage Inversé
Просмотров 183Год назад
FAAST FLEX Procédure: Montage Inversé
FAAST FLEX Procédure: Modification du Code
Просмотров 269Год назад
FAAST FLEX Procédure: Modification du Code
FAAST FLEX Procédure: Mise en Service et Configuration
Просмотров 515Год назад
FAAST FLEX Procédure: Mise en Service et Configuration
FAAST FLEX Procédure: Installation Verticale
Просмотров 373Год назад
FAAST FLEX Procédure: Installation Verticale
FAAST FLEX: How-To Pair Your Bluetooth
Просмотров 1,7 тыс.Год назад
FAAST FLEX: How-To Pair Your Bluetooth
FAAST FLEX: How-To Set Up for Bluetooth
Просмотров 4,2 тыс.Год назад
FAAST FLEX: How-To Set Up for Bluetooth
Li-ion Tamer Gen 3
Просмотров 5 тыс.Год назад
Li-ion Tamer Gen 3
Xtralis University - Booker Admin "How-To"
Просмотров 206Год назад
Xtralis University - Booker Admin "How-To"

Комментарии

  • @neXor1987
    @neXor1987 3 месяца назад

    Is it possible that a source of light, such as a lamp can be seen as a beam blockage fault?

  • @peterpepple
    @peterpepple 8 месяцев назад

    What's the major difference between VESDA-E-VES and VESDA-E-VEP?

  • @joaquinsegundoortiz3055
    @joaquinsegundoortiz3055 8 месяцев назад

    Y una mierda da para vosotros unos minutos menuda guarrería de sustema

  • @sureshreddy9332
    @sureshreddy9332 11 месяцев назад

    Need more videos

  • @sureshreddy9332
    @sureshreddy9332 Год назад

    What is the flow error cause

  • @kalebflores9417
    @kalebflores9417 Год назад

    I have no Bloody Locking Screw

  • @missy4304
    @missy4304 2 года назад

    Ja ik ben er toch nog aangedaan geweest sorry Vooral omdat ik niks meer gehoord had en ik ni direct durfde sturen. Omj ou ni boozer te maken

  • @joaopnz
    @joaopnz 2 года назад

    Hold on, to way you say it it seems like you don't need an HLI to connect to a VLP, that doesn't sound right!

  • @anshsindhva228
    @anshsindhva228 2 года назад

    Continue lighting what problems

  • @sharonshanmughan270
    @sharonshanmughan270 3 года назад

    I'm getting a system init mode error on the panel can anyone give me a solution for this ?

  • @90sninetiesmaragh2
    @90sninetiesmaragh2 3 года назад

    Connect 3 of these to a edwards addressable system through a module. I keep getting a open fault.

  • @siixlogis
    @siixlogis 3 года назад

    I am interested in your OSID-R Smoke Beam Detector with 100 meter range. Can this Beam Detector be connected to the Cooper Conventional Fire Alarm Control Panel model FX2204 ?

  • @imransafdar5574
    @imransafdar5574 3 года назад

    Thank you

  • @markthompson6540
    @markthompson6540 3 года назад

    How to connect to When in reality it is a sales talk for a convertor

  • @fherrera120
    @fherrera120 4 года назад

    Does this mount directly to a 4sq. Box?

  • @lurdinhalima7236
    @lurdinhalima7236 4 года назад

    Ñ consigo acessar minha conta site da OSID p fazer doação

  • @shAli5388
    @shAli5388 4 года назад

    ruclips.net/video/DUrY49MJfZk/видео.html ruclips.net/video/Zwazkp7n9XQ/видео.html Connect VESDA with VSC software

  • @shAli5388
    @shAli5388 4 года назад

    Connect VESDA with VSC Software ruclips.net/video/Zwazkp7n9XQ/видео.html ruclips.net/video/DUrY49MJfZk/видео.html

  • @SanthoshKumar-nb5ru
    @SanthoshKumar-nb5ru 4 года назад

    Please explain the compact vesda panel details

  • @mattflak5415
    @mattflak5415 5 лет назад

    Arrows will not align properly, just blinks red and when it does go yellow the beam is no where near reflector

    • @antonios4926
      @antonios4926 4 года назад

      Did u get it going? So its not worth buying one?

    • @antonios4926
      @antonios4926 4 года назад

      Which model did u buy?

    • @Yabo-
      @Yabo- 4 года назад

      ANTONIOS they work very well. The problem I experienced is on earlier versions of the silent knight 6820 firmware the detector did not hold its alignment. When removing all power from slc I would have to grab the 40ft ladder and redo the initialization process. This has been ressolved recently

    • @sharonshanmughan270
      @sharonshanmughan270 3 года назад

      Have you got an init mode error on the panel?

  • @khurrampasha1982
    @khurrampasha1982 5 лет назад

    Audio is not clear due to the fan sound.

  • @mariohenrique2555
    @mariohenrique2555 6 лет назад

    Great! Commissioning Technician in Brazil

  • @luckygupta1786
    @luckygupta1786 6 лет назад

    It this applicable open coal storage yard & is coal or cement dust Able to falls the alarm Plz reply My mail is lucky.gupta@prismjohnson.in

  • @florescruzvisuals
    @florescruzvisuals 7 лет назад

    Is the alignment radius D/120? So D=distance? So if my distance is 250/120 I get roughly 2.02 would my radius be 2 feet?

  • @rehammohamed1835
    @rehammohamed1835 8 лет назад

    what mean IR and UV in this video ?

    • @snooks5607
      @snooks5607 5 лет назад

      infrared and ultraviolet

  • @edgarcarranza3566
    @edgarcarranza3566 10 лет назад

    que tal no tendran un video de la configuracion por medio del software osid diagnostic tool saludos!!